The Gas and Oil Fired WNS Series Automatic Hot Water Boiler represents the pinnacle of industrial heating efficiency, engineered with a sophisticated horizontal wet-back and three-backhaul structure. This advanced design ensures a compact footprint and an optimized layout, making it an ideal solution for facilities with limited boiler room space without compromising on thermal performance.
Integrating high-performance components such as corrugated furnaces and spirally corrugated tubes, the WNS series significantly enhances turbulent heat transfer and effectively manages thermal expansion. Combined with a low-level combustion chamber for maximum water level safety and world-renowned burner brands, this boiler delivers unparalleled reliability, safety, and high energy efficiency for diverse industrial applications.
Detailed Parameters
| Rated Pressure | 1.0 Mpa | Outlet Water Temp | 95/115 ℃ |
|---|---|---|---|
| Inlet Water Temp | 70 ℃ | Efficiency Range | 92.4% - 93.2% |
| Capacity Range | 0.7MW - 14MW | Heating Surface | 25.6㎡ - 426㎡ |
| Fuel Options | Natural Gas / Diesel Oil | Structure Type | Horizontal Wet-back |
| Weight Range | 4.5t - 41t | Combustion Tech | Automatic Burner |
Key Advantages
Enhanced Safety
Low-level combustion chamber design reserves ample water level safety space to minimize risks of water shortage accidents.
Space Optimized
Finned tube economizer arrangement allows for a compact shape, perfectly suited for smaller industrial boiler rooms.
High Efficiency
Premium fire-proof and insulation materials lower surface temperatures and significantly boost overall thermal efficiency.
Advanced Heat Transfer
Corrugated furnace and spiral tubes intensify turbulent heat transfer and relieve thermal expansion stresses.
World-Class Components
Equipped with international famous brand burners to ensure the highest standards of quality, stability, and safety.
Automatic Operation
Fully automatic control systems reduce manual intervention and ensure consistent water temperature output.
Product Gallery
Management Platforms
Fuel Management
Dual-fuel flexibility allowing seamless switching between gas and diesel based on cost and availability.
Thermal Control
Precision modulation of the combustion process to maintain optimal outlet temperatures (95/115℃).
Safety Monitoring
Real-time monitoring of water levels and pressure to prevent overheating or dry-firing accidents.
Efficiency Tracking
Automated tracking of gas/diesel consumption against heat output for operational cost analysis.
Layout Optimization
Compact dimensions managed for rapid installation and minimal site preparation.
Maintenance Alerts
Scheduled maintenance prompts based on burner run-time and heat surface scaling cycles.
Investment Return Comparison
| Feature | Standard Boiler | WNS Series Boiler |
|---|---|---|
| Thermal Efficiency | 85% - 88% | 92.4% - 93.2% |
| Space Requirement | Large footprint | Compact/Optimized |
| Safety Risk | Medium (Standard) | Low (Low-level Chamber) |
| Heat Transfer | Linear Tubes | Corrugated/Spiral Tubes |
| Fuel Versatility | Single Fuel | Gas/Diesel Dual Option |
Frequently Asked Questions
The wet-back design reduces the need for refractory materials in the rear chamber, lowering maintenance costs and improving overall heat transfer efficiency by keeping the heating surfaces submerged in water.
Corrugated tubes create turbulent flow in the flue gas, which significantly increases the heat transfer coefficient compared to smooth tubes, while also allowing for better thermal expansion without stressing the boiler structure.
Yes, the WNS series is designed for versatility. Depending on the burner configuration, it can be operated as a gas-fired or diesel-fired boiler, providing operational flexibility based on local fuel pricing.
We employ a low-level combustion chamber design which creates a larger water level safety buffer, reducing the risk of accidents caused by sudden water loss or sensor failure.
The economizer recovers waste heat from the flue gases to preheat the incoming feed water, which significantly lowers fuel consumption and increases the overall boiler efficiency.
With proper water treatment and regular maintenance of the international-brand burners, these boilers are engineered for long-term industrial durability, typically lasting several decades.
Ready to Optimize Your Industrial Heating Efficiency?
Contact Us-
Котел за термално масло монтиран на лизгање
16750
160
Вертикален котел за термално масло со вертикална решетка на јаглен со синџир YLL
16750
162
Парен котел со автоматска решетка со синџир DZL на јаглен или биомаса
16750
168
Хоризонтален котел за термално масло на гас YQW
16750
158
WNS парен котел со гас или дизел за заштеда на енергија
16750
165
Котел за термално масло со фиксна решетка YGL на биомаса
16750
163
Електрично греење WDR автоматски парен котел
16750
170
Latest News-
How to Choose a Water Tube Gas Fired Steam Boiler for Plant IntegrationChoose an SZS water tube gas fired steam boiler by steam capacity, pressure, fuel demand, outlet size, shipping dimensions and plant access.Detail -
Hebei Yineng Boiler Co., Ltd. Successfully Concludes Its Participation in the Indonesia Boiler ExhibitionHebei Yineng Boiler Co., Ltd. is pleased to announce the successful conclusion of its participation in the Indonesia Boiler Exhibition.Detail -
Vertical YLL coal fired chain grate thermal oil boiler vs DZL steam boilerCompare the Vertical YLL coal fired chain grate thermal oil boiler with the DZL steam boiler by pressure, temperature, efficiency, fuel handling, interfaces, and maintenance.Detail