Choosing a Gas Oil Fired WNS Seires Automatic Hot Water Boiler for Your Boiler Room



The Gas oil fired WNS seires automatic hot water boiler suits facilities that need hot water from 0.7 MW to 14 MW and can accommodate its horizontal wet-back layout. Choose the model by required capacity, water temperatures, fuel consumption, connection size, and boiler-room access.

Choosing a Gas Oil Fired WNS Seires Automatic Hot Water Boiler for Your Boiler Room
Illustration for reference; see the product page for actual photos and specifications.

The right model depends first on the heat load and water circuit, then on the space available for the boiler and its connections. Our Gas oil fired WNS seires automatic hot water boiler line covers WNS0.7 through WNS14, with a rated pressure of 1.0 Mpa, inlet water at 70 ℃, and outlet water at 95/115 ℃.

Match capacity to the heating load

Select the WNS model from the required capacity instead of using the largest available unit. The line covers 0.7 MW, 1.4 MW, 2.1 MW, 2.8 MW, 4.2 MW, 7.0 MW, 10.5 MW, and 14 MW. Each capacity is paired with a different gas or diesel consumption, weight, heating surface, and footprint.

ModelCapacity (MW)Efficiency (%)Gas consumption (Nm³/h)Diesel consumption (kg/h)
WNS0.70.792.575.562.5
WNS1.41.492.7151.5122.4
WNS2.12.192.4224.2186.9
WNS2.82.892.5298.2249.2
WNS4.24.292.9450.2374.6
WNS7.07.093.2751.8622.3
WNS10.510.592.61128.9930.1
WNS141492.71502.61245.6

Use the fuel column that matches your planned burner fuel when checking operating consumption. The heating surface ranges from 25.6 ㎡ to 426 ㎡ across the models, so capacity selection also affects the heat-transfer area and equipment size.

Choose this line for hot-water systems within its listed capacity and temperature range. Lower-capacity models suit sites with smaller loads and room dimensions; WNS7.0, WNS10.5, and WNS14 suit higher listed capacities when the larger equipment can enter and fit the boiler room. Confirm fuel, circuit conditions, access dimensions, and outlet DN before requesting a configuration.

Check the water circuit before ordering

The boiler is suited to hot-water systems designed around a 70 ℃ inlet and a 95/115 ℃ outlet. Confirm that the connected heating circuit, pumps, controls, and end-use equipment can work with these temperatures before choosing a model.

The rated pressure is 1.0 Mpa. Your system design should therefore be reviewed against this rating, along with the required water outlet connection. The water outlet sizes run from DN 80 on WNS0.7 to DN 250 on WNS14, with intermediate models using DN 100, DN 125, or DN 200 connections.

Fit the boiler into the room

A horizontal wet-back, three-backhaul structure and finned tube economizer arrangement keep the boiler shape compact for a smaller boiler room. The actual model still needs a room check because dimensions increase with capacity.

ModelLength L (mm)Width W (mm)Height H (mm)Weight (t)
WNS0.73600180019504.5
WNS1.44200206022707.5
WNS2.14550220024008.9
WNS2.848302360259010.3
WNS4.257802560283013.5
WNS7.065502970326021
WNS10.574703470377032.5
WNS1479003670405041

Measure the available route into the boiler room against the selected model's length, width, and height. Include space for the DN water outlet connection and the equipment arrangement around the boiler when planning the installation location.

Use the construction details to judge fit

Corrugated furnace and spirally corrugated tubes intensify turbulent heat transfer and help relieve thermal expansion of the furnace body. These features suit buyers looking for a compact horizontal boiler with a defined hot-water operating range.

The low-level combustion chamber reserves water-level safety space to minimize the risk of water shortage accidents. Fire-proof and insulation materials lower the boiler surface temperature and improve thermal efficiency. The burner is an international brand component, and the boiler uses a wet-back structure with three-backhaul flue-gas routing.

What to weigh

Heating load · match the required output to 0.7 MW through 14 MW

Water circuit · check 70 ℃ inlet, 95/115 ℃ outlet, and 1.0 Mpa rating

Room access · compare model dimensions, weight, and DN water outlet

Fuel planning · compare gas or diesel consumption for the selected model

Your shortlist

Gas oil fired WNS seires automatic hot water boiler, models WNS0.7 through WNS14

Select the model that matches your site

Choose WNS0.7 through WNS4.2 when your required capacity falls within the line's lower capacity range and the smaller dimensions suit the room. Choose WNS7.0, WNS10.5, or WNS14 when the heating load requires those capacities and the site can receive the corresponding larger equipment.

Before requesting a configuration, send us the required heating capacity, fuel type, inlet and outlet water conditions, available boiler-room dimensions, and required water outlet DN. We can then match the request to the applicable WNS model.

The company

Hebei Yineng Boiler Co., Ltd

It is located in Wuqiao, Hebei Province, a famous acrobatic town in the world. It has a branch company Shandong Yieneng Boiler Co., Ltd. in Dezhou, Shandong. The company covers an area of ​​more than 300 acres and a production workshop of 80,000 square meters. Fixed assets of 150 million yuan. More than 300 employees, more than 120 various types of engineering and technical personnel.…