Specifications
It adopts wet-back internal combustion two-pass structure with compact structure and high boiler efficiency.
The use of micro-positive pressure operation effectively improves the combustion intensity of the furnace door, making the volume of the boiler with the same capacity smaller, and at the same time eliminates the air leakage of the boiler furnace door and flue, and improves the thermal efficiency of the boiler.
Adopt advanced EDA technology to calculate the structure and size of the furnace body and the flow rate of flue gas in detail, make full use of flame and flue gas heat exchange reasonably, ensure reliable operation and sufficient cooling of the boiler, and improve the thermal efficiency of the boiler.
4 Adopt high-efficiency condensation technology, which effectively reduces the exhaust gas temperature and improves the thermal efficiency of the boiler.
Reasonable structural design and excellent refractory and heat-insulating materials are adopted to greatly reduce the surface temperature of the furnace body, making the surface temperature lower than 50 degrees (higher than the national standard), reducing heat loss and improving the thermal efficiency of the boiler.
Adopt a new design to reduce the emission of harmful substances during fuel combustion and meet the national environmental protection standards, especially reduce the emission of nitrogen oxides to meet the national low nitrogen emission standards.
It adopts imported burners of many well-known international brands, adapts to various application scenarios, guarantees quality and safety Complete.
Using PLC and other automation controllers of international brands such as Siemens as the control core, equipped with peripheral components from well-known manufacturers to realize the automatic control system of the boiler, which can collect the temperature of the inlet and outlet in real time.
Various parameters such as pressure are displayed centrally in the control cabinet in real time, and closed-loop control systems such as PID ensure thatThe boiler works stably under various parameters such as the temperature set by the user, and at the same time monitors the working range of the data, and reminds or alarms various temperature rises, which is convenient for users to use and maintain.
The control module also has powerful expansion capabilities, and can conveniently realize various in-depth applications such as group control and remote control according to customer needs.
TECHNICAL PARAMETER
|
Capacity |
KW |
450 |
1400 |
2000 |
2400 |
3000 |
4700 |
|
|
X10⁴Kcal/h |
40 |
120 |
160 |
200 |
250 |
400 |
||
|
Mpa |
1.1 |
|||||||
|
Max. temperature (℃) |
450 |
|||||||
|
Circulating oil volume (m³/h) |
18 |
30 |
30 |
60 |
80 |
100 |
||
|
Molten salt volume (m³) |
0.61 |
1.65 |
1.9 |
2.41 |
3.5 |
5 |
||
|
Efficiency (%) |
96.09 |
96.28 |
96.27 |
96.02 |
96.00 |
96.06 |
||
|
Connecting pipe diameter (DN) |
65 |
125 |
125 |
150 |
150 |
200 |
||
|
Boiler weight (kg) |
4384 |
7469 |
9725 |
10826 |
15330 |
16657 |
||
|
(mm) Dimension |
W (Φ) |
1670 |
1946 |
2136 |
2340 |
2700 |
2900 |
|
|
H |
4249 |
5629 |
5876 |
6570 |
7365 |
8070 |
||